7. Attention to environmental protection requirements, low emission pollution
Product details
OVERVIEW
GENSET MODEL
RATED POWER(kW/kVA)
STANDBY POWER (kW/kVA)
DIESEL ENGINE
MEASUREMENT (mm)
WEIGHT(kg)
MODEL
RATED POWER
(kW)
OWELL-RI8OP
8/10
8.8/11
YSAD380D
10.3
1860x800x950
700
OWELL-RI10OP
10/12.5
11/13.75
YD480D
14
1860x800x950
700
OWELL-RI12OP
12/15
13.2/16.5
YD480D
14
1860x800x950
700
OWELL-RI16OP
16/20
17.6/22
YSD490D
21
2050x880x1050
800
OWELL-RI20OP
20/25
22/27.5
K4100D
30
1600x640x1000
680
OWELL-RI24OP
24/30
26.4/33
K4100D
30
1600x640x1000
680
OWELL-RI30OP
30/37.5
33/41.25
K4100ZD
42
1700x700x1100
790
OWELL-RI30OP
30/37.5
33/41.25
K4102D
33
1700x700x1100
790
OWELL-RI40OP
40/50
44/55
K4100ZD
42
1870x720x1250
860
OWELL-RI40OP
40/50
44/55
N4105ZD
56
1870x720x1250
860
OWELL-RI50OP
50/62.5
55/68.75
R4105ZD
56
1870x720x1250
860
OWELL-RI50OP
50/62.5
55/68.75
N4105ZD
56
1870x720x1250
860
OWELL-RI60OP
60/75
66/82.5
R6105ZD
84
2210x720x1380
910
OWELL-RI60OP
60/75
66/82.5
R4105ZLD
66
2210x720x1380
910
OWELL-RI60OP
60/75
66/82.5
N4105ZLD
66
2210x720x1380
910
OWELL-RI80OP
80/100
88/110
R6105ZD
84
2210x720x1380
910
OWELL-RI100OP
100/125
110/137.5
R6105AZLD
110
2340x720x1550
1350
OWELL-RI120OP
120/150
132/165
R6105IZLD
132
2570x775x1725
1450
OWELL-RI150OP
150/187.5
165/206.25
R6113ZLD
155
2570x775x1725
1650
OWELL-RI150OP
150/187.5
165/206.25
R6110ZLD
170
2570x775x1725
1650
OWELL-RI160OP
160/200
176/220
R6126ZLD204
204
2950X1150X1700
2150
OWELL-RI200OP
200/250
220/275
R6126ZLD235
235
2950X1150X1700
2150
OWELL-RI250OP
250/312.5
275/343.75
R6126ZLD288
288
3250x1250x1830
2350
Note: Specifications based on 1500RPM, 50HZ, 230/400V, power factor 0.8, 3 phase 4 wire system. 60HZ generator set can be customized
Quality & Testing
Production & management follow ISO9001:2015 requirement, each generator must be passed strict inspection in each progressing.
1. All the raw materials/parts by IQC (Incoming Quality Control) before launch into process.
2. Each generator/part under control of IPQC (Input Process Quality Control).
3. Each generator/part must be pass 100% inspection between process.
4. All-sided ex-factory testing in various condition (Outgoing Quality Control), test items as following.
>Loading test in 0%, 25%, 50%, 75%, 100%,
>Heat run test
>Insulation resistance test
>Frequently starting test
>Alarm and timing relays test.
WORKSHOP
Packing & Delivery
User Evaluation
Inquire Now